Bilro Logo

Architectural Details - Free for Download

 

Home

These are architectural details that suit New Zealand conditions.They are METRIC! They were done around 2004, so they may be out
of date by now. Please see my disclaimer page. I make no claims as to the accuracy or viability, so check each one suits your needs!
I have used the Technical Font, which is an semi hand written font. You can find this easily on the internet and download it for free.
The file names have abbreviations at the start, giving an idea as to what subdirectory I had them stored under. Rather than have heaps
of pages, they are all on this one.
The abbreviations are: DTH=Decks to House, DE=Decks-Outer Edge,FB=Floor Beams,FP=Foundation Posts, F=Foundations, G=Gutters,
M=Miscellaneous, R=Roofs, SD=Steelwork Details, WALL=Walls.  
Click on the links below to download files.

DTH-150X50 Joists-Deck Sloping to House DTH-150X50 Joists-to Weatherboards-to Existing Solid Lower Conc Wall DTH-150X50 Joists-to Weatherboards-to Existing Wall DTH-200X50 Joists-to Weatherboards-to Existing Solid Lower Brick Wall DE-150x50 Joists-100 Posts-Panelled-Planked Deck DE-150x50 Joists-40 X 40 Balusters-Railing on Edge-Butynol-Planked Deck DE-150x50 Joists-40 X 40 Balusters-Railing on Flat-Planked Deck DE-150x50 Joists-50 X 50 Balusters-Railing on Flat-Planked Deck-Sandwich Style DE-150x50 Joists-50 X 50 Balusters-Railing on Flat-Planked-Sandwich Style Bearer Type DE-150x50 Joists-Panelled-Railing on Flat-Planked Deck DE-200x50 Joists-40 X 40 Balusters-Railing on Edge-Planked Deck DE-Solid 100 x 50 Railing-Butynol-to Adjacent-Tile Roof FB-Even Joists Joining to I Beam-250UB31-200 Joists FB-Even Joists Joining to I Beam FB-I Beam at Wall Edge-to Deck FB-Uneven Sizes of Joists Joining to I beam FP-100 x 100 Post into Conc Footing FP-100 x 100 Post on Bowmac B18-Conc Footing FP-100 x 100 Post on Bowmac B28 on top of Conc FP-100 x 100 Steel Post into Conc Footing FP-125 x 125 Senton Post into Conc Footing FP-150 Dia Tanapole Post into 1200 deep x 300 dia Conc Footing F-Bearers 250x50 and 200x50 Meeting at top of Pole at rt angles F-Slab Joining to Existing Slab Edge Foundation F-Slab to Permanent Outside Paving -Brick Veneer-On 40mm Polystyrene-with Bond Beam F-Slab to Permanent Outside Paving- On Sand-with T and G Flooring F-Slab to Permanent Outside Paving F-Slab to Unprotected Ground-On 40mm Polystryrene-Cavity-400x400-WB F-Slab to Unprotected Ground-On 40mm Polystryrene-Cavity-WB F-Slab to Unprotected Ground- On Sand-with T and G Flooring F-Slab to Unprotected Ground-3D Conc Walls F-Slab to Unprotected Ground-On 30mm Polystyrene F-Slab to Unprotected Ground-On Sand F-Slab Transition to Wooden Floor-On 30mm Polystyrene F-Slab Transition to Wooden Floor-On Sand-with T and G Flooring F-Slab Transition to Wooden Floor-On Sand F-Slab Underneath Load Bearing Wall-On 30mm Polystyrene F-Slab Underneath Load Bearing Wall-On 40mm Polystyrene F-Slab Underneath Load Bearing Wall-On Sand-with T and G Flooring F-Slab Underneath Load Bearing Wall-On Sand F-Slab with Masonry Veneer - 1200 to Unprotected Ground on 200 Insulation F-Slab with Masonry Veneer to Permanent Outside Paving-Single Bond Beam Only F-Slab with Masonry Veneer to Permanent Outside Paving F-Slab with Retaining Wall to Outside Paving-On Sand -2500 to Ground F-Slab with Upstand to Unprotected Ground-1 Block High F-Slab with Upstand to Unprotected Ground-2 Blocks High F-Timber Floor on Senton Piles next to Existing Brick Foundation-with Joist Hangers Timber Floor on Senton Piles next to Existing Brick Foundation Timber Floor on Senton Piles-Adding to Existing F-Timber Floor on Senton Piles-Extending from Existing-with Timber Deck F-Timber Floor on Senton Piles-Extending from Existing F-Timber Floor on Senton Piles-Next to Conc Driveway-Foundation for Driveway F-Timber Floor Over Conc Foundation-Inside Under House-On 30mm Polystyrene F-Timber Floor Over Conc Foundation-Inside Under House-On Sand F-Timber Floor over Conc Foundation-Outside Paving-Joists Inside F-Timber Floor Over Conc Foundation-to Unprotected Ground-Joists on Top F-Timber Floor to Conc Foundation Wall-with Level Change F-Timber Floor to Conc Foundation-with Level Change G-Internal Gutter-Roof Either Side G-Internal Gutter-Wall with Wall-Roof G-Internal Gutter-Wall with Window-Roof M-Handrail M-Pergola Beam to Wall-WB M-Vertical Weatherboards-Pipe Penetration M-Weatherboards-Pipe Penetration-Cavity R-Butynol-Corner Folding R-Butynol-with Gutter R-Diagram of Rafter Fixings R-Eave with Gutter-GN-450 FS-25-Brick Column-MTR-200 Lintel R-Eave with Gutter-GN-450 FS-25-Brick Veneer-MTR R-Eave-With Gutter-GN-280-Clay Tile-30-No EF R-Eave-With Gutter-GN-600-PM-10-EF R-Eave-With Gutter-GN-600-PM-10-No EF R-Eave-With Gutter-GN-SS-600-PM-10-EF-Cavity R-Eave-With Gutter-GN-SS-600-PM-10-EF R-Eave-With Gutter-R-600-PM-10-EF-Cavity R-Eave-With Gutter-R-600-PM-10-EF R-Eaves-No Gutter-GN-600-PM-10-CAVITY R-Eaves-No Gutter-GN-600-PM-10 R-Eaves-No Gutter-R-600-PM-10-CAVITY R-Eaves-No Gutter-R-600-PM-10 R-R-Cross Beam-10-PM R-To Wall-Cavity-PM-10-HWZ R-To Wall-PM-10-HWZ R-To Wall-PM-10-LWZ R-To Wall-R-PM-10-with Parapet R-Verge-Barge Flashings-GN-450-PM-Cavity R-Verge-Barge Flashings-GN-500-PM-Cavity R-Verge-Barge Flashings-GN-600-PM-No Outriggers R-Verge-Barge Flashings-R-450-PM-Cavity R-Verge-Barge Flashings-R-500-PM-Cavity R-Verge-Barge Flashings-R-600-PM R-Verge-Barge Flashings-R200-450-PM R-Wall Junction-PM-HWZ-Cavity SD-Column and Beam at Garage Door SD-I-Beams at Right Angles Wall-Bricks on Lower Floor-Timber Cladding on Upper Floor Wall-Bricks-Weatherboard-Butynol ALL-STUDS AND LINTEL DIAGRAM